Energy Save

Energy Save

New Thermostatic head te-sa

In order to provide its customers with updated and high quality products with pleasant aesthetic and ergonomic features, te-sa deiced to introduce in its range a new thermostatic head with liquid sensor bulb. It is compact and easy to use for the end user that must be able to easily manage the energy emitted from radiators installed in their houses.

Adjusting the temperature inside the rooms is a legal obligation, but especially an important help for saving money. If the correct management of the temperature of the rooms is Obtained thanks to simple and functional tools, the end-user will obtain comfort, energy savings, reduction of fuel consumption and consequently an immediate reduction of system operating costs.

The new thermostatic head 116 is little but with high accuracy in ADJUSTING room temperature, its little dimensions allow its assembly on radiator valves also In cases where space is limited. Easy Installation, a smooth and pleasant body that will avoid annoying dust accumulations difficult to remove
The setting position can be easily identified thanks to a slider with proper dimensions; it is also clearly visible to the elders or people with poor sight.
The head 116 allows to adjust the ambient temperature in a range between 10 ° C and 26 ° C, with a downward extension with the frost protection function settled at 6 ° C. It has an extension of full scale at 28 ° C corresponding to “all open” condition (summer function when the installation is off, this position is recommended to maintain system components efficient).

Equipped with ring with M30x1, 5 thread suitable for installation on all radiator valves

116-01
116-01

Technical features

  • Performance with te-sa thermostatic valves conform to EN215 thermostatic head with liquid sensor
  • setting temperature range to 28 ° C 6
  • Maximum static system pressure 10 bar
  • Maximum differential pressure of 1.2 bar
  • Maximum water temperature 110 ° C
  • Hysteresis 0.8 K
  • Flow coefficient thermostated valves from 1/2 “to 0.8 KV to adjustment s-2K
  • Mounting position : horizontal recommended
  • Connecting ring to the valve body M30x1,5 in chromed brass

Temperature adjusting scale

0 1 2 3 4 5
Closed 6° C 12° C 16° C 20° C 24° C 28° C

 Download the technical datasheet in PDF format


 

Gruppo di miscelazione
Disegno tecnico Gruppo di miscelazione

The New thermostatic mixing unit for radiant floor systems 248th

The thermostatic mixing group 248th, combined with a te-sa distribution manifold, allows to have the water distribution in the floor heating system maintaining a constant flow temperature at a fixed value settled by the user in the range of 25 ÷ 60 ° C.

Adjusting the temperature inside the rooms is a legal obligation, but especially an important help for saving money. If the correct management of the temperature of the rooms is Obtained thanks to simple and functional tools, the end-user will obtain comfort, energy savings, reduction of fuel consumption and consequently an immediate reduction of system operating costs.

Its morphology Enables itself to operate correctly Also During applications where the supply temperature of the group is slightly higher than the settled one for the delivery to the panels. Example of use: in cases of a heat pump generator, solar heating or district heating, where, the traditional injection groups with thermostatic valve and thermostatic head with capillary sensor bulb  have difficulty in mixing water, therefore are not able to reach the desired delivery Water temperature in an acceptable time, or sometimes because the residual requested injection is too High.

Equipped with electronic circulator and safety thermostat pre-wired, it is appreciated for its simplicity and use flexibility, especially in limited power applications, where it is not convenient to adopt an electronic control unit combined with a mixing valve.

The eccentric pipe unions of the group allow coupling to the distribution manifold even where the mounting distances differ slightly from the nominal ones.

Realized with mixing by thermostatic bulb, this mixing group is studied for floor heating systems combined to manifold 220 in various available configuration.

Technical data

  • Manifold with self-sealing adaptors 1 “M
  • SETTING field mixer 20 to 60 ° C
  • Kv = 2.9
  • Electronic circulator Wilo Yonos Para 25 / 1-6
  • Check valve against the natural circulation pre-assembled on the secondary
  • Pre-assembled Security thermostat 55 ° C
  • Thermometer on the main flow enter
  • Overall dimensions H x W x D (mm) 400 x 210 x 120
  • Adjustable manifolds distances in 205/255 mm

Pressure drop

Perdita di pressione